Furnace passing its safety checks but starving for air
This 2013 gas furnace passed every safety check, but the measurements showed a blower working far too hard. The blower wheel and return duct were heavily coated, and the motor was drawing well over its rating.
What we found
Findings and readings
- No gas leaks. The heat exchanger, flue venting and safety controls checked out.
- The blower wheel and return ductwork were heavily coated with dirt and debris.
- The blower motor drew 7.35 amps against its 4.7 amp rating.
- Temperature rise measured 52°F. This furnace is rated for 20 to 50°F.
- The blower capacitor tested 11.79 µF on a 12.5 µF rating, 5.7% low.
- The burners were dirty but not yet affecting combustion.
| Check | Reading | Result |
|---|---|---|
| Blower motor amps | 7.35 A vs 4.7 A rated | High |
| Temperature rise | 52°F (rated 20–50°F) | Over |
| Blower capacitor | 11.79 µF on 12.5 µF | Weak |
| Gas leak test | No leak found | Pass |
| Thermostat accuracy | 70.0°F vs 70.2°F | Pass |
Photos from the job
What it looked like


What we did
Work completed
- Completed the safety inspection: gas leak test, heat exchanger, flue and safety controls
- Removed and cleaned the flame sensor
- Measured amps, temperature rise, static pressure and capacitor values
What we recommended
Next steps for this system
- Blower wheel removal and cleaning
- Return duct cleaning
- Replace the weak blower capacitor
- Burner cleaning
Real job from our service records. Customer names, street addresses and equipment serial numbers are left out; photos show the equipment only.
More recent jobs
Other jobs we have documented

Frederick, MD · November 2026
Full system cleaning and a UV light with carbon filter
Maintenance plan visit
Read the job report →
Washington, DC · November 2026
Condo furnace that kept shutting off on cold nights
No-heat service call
Read the job report →
Chevy Chase, MD · November 2026
Attic air handler humming and over-amping
Maintenance plan visit
Read the job report →See all recent jobs · Clarksburg & Boyds · 55-point inspection
Seeing something similar?
Send a quick request and Josh will text you back, or pick a time online. For no heat or no AC, call.
Emergencies: call 240-483-9872, answered 24/7.